Insulation Supply Co.                  800-457-7715

  Tyco/Raychem
 Industrial Medical Materials

Altera MT1000
Operating Temperature Range: -55C to 175C
Features:
* 2:1 shrink ratio
* Tough, semirigid, very-thin-wall insulation.
* Excellent resistance to a variety of fluids.
* Optional inner adhesive lining.
* UPS Class VI material, no heavy metals.
* Plastic spools or double-bagged packaging.
* Compatibility with autoclave, gamma, ETO, steam, and dry-heat sterilization.
* Min shrink temp: 155C Full Recover: 175C
* Color; Standard, Translucent (-X)

Applications....

Ideal for electrical insulation and strain relief of components that are exposed to high temperatures - either during operation or during sterilization. Thin-wall construction is well suited for applications with clearance constraints.

 

Altera MT2000
Operating Temperature Range: -40C to 105C
Features:
* 2.5:1 shrink ratio
* Excellent electrical insulation properties.
* Can be manufactured with a very thin wall.
* Optional inner adhesive lining.
* UPS Class VI material, no heavy metals.
* Plastic spools or double-bagged packaging.
* Compatibility with gamma and ETO, sterilization.
* Min shrink temp: 110C Full Recover: 140C
* Color; Standard, Black (-0), Clear (-X)
 

Especially suitable for medical application requiring lubricity, Flexibility, and excellent electrical insulation performance. A const-effective alternative to FEP (fluorinated ethylene-propy-lene) while maintaining performance after gamma sterilization.

 

Altera MT3000
Operating Temperature Range: -55C to 150C
Features:
* 2:1 shrink ratio
* Tough, flexible, very-thin-wall insulation.
* Excellent resistance to a variety of fluids.
* UPS Class VI material, no heavy metals.
* Plastic spools or double-bagged packaging.
* Compatibility with autoclave, gamma, ETO, steam, and dry-heat sterilization.
* Min shrink temp: 110C Full Recover: 150C
* Color: Standard, Black (-0)
 

Ideal for electrical insulation and strain relief of components that are exposed to high temperatures - either during operation or during sterilization. Thin-wall construction is well suited for applications with clearance constraints.

 

Altera MT5000
Operating Temperature Range: -70C to 107C
Features:
* 2:1 shrink ratio
* Flexibility; variety of colors.
* Excellent electrical insulation properties.
* Inner adhesive-lined optional
* UPS Class VI material, no heavy metals.
* Plastic spools or double-bagged packaging.
* Compatibility with gamma, ETO sterilization.
* Min shrink temp: 90C Full Recover: 110C
* Color: Standard, Black (-0), Clear (-X)
 

Ideal for electrical insulation and strain relief of components that are exposed to high temperatures - either during operation or during sterilization. Thin-wall construction is well suited for applications with clearance constraints.

 

ZEUS 
 
Industrial Medical Materials

Medical Quality Teflon Tubing  
SPC, CPK, USP CLASS VI Approved  
PTFE, Sub-Lite-Wall (Extruded and Heat Shrinkable Tubing
Extruded Tubing (PTFE, FEP, PFA, ETFE) -AWG measurements
Extruded Tubing (PTFE, FEP, PFA, ETFE - Fractional measurements
Heavy Construction Tubing (PTFE, FEP, PFA, ETFE)
Sprial-Cut Cable Wrap
Miniature Rod and Round Beading
Heat Shrink Tubing
  • PTFE 2 to 1 Shrink Ratio (AWG) (measurements)
  • PTFE 2 to 1 Shrink Ratio (Fractional measurements)
  • PTFE 4 to 1 Shrink Ratio
  • PTFE/FEP DUAL-Shrink Tubing  
  • FEP 1.3 to 1 Shrink Ratio 
  • FEP 1.6 to 1 Shrink Ratio
  • Dual-Tube (For Water Monitoring)
  • Splines (Wire, Cables, Coaxial Cores)
 
The Tubing Integrity You Require - from IV Sets to PTCA and HPLC Applications
Ranging from IV sets, analytical instruments and laparoscopic
devices - to the finite tolerances of PTCA and HPLC applications, ZEUS provides the tubing integrity and support you require.

Proven in innumerable medical applications, ZEUS fluoropolymer tubing is carefully monitored for integrity via a variety of precision, state-of-the-art quality control equipment.

 

Zeus is a resource tool for your concepts, ideas - your innovative inspirations. From custom specifications and tight tolerances, to suggestions, special assistance and samples

Samples, Service - Custom Specifications
The fluoropolymer properties developed in ZEUS medical tubing features superior flow-through rate, durability and precision characteristics unequaled in any other type of tubing. ZEUS can supply your extrusions in a variety of lengths - continuous or precision-cut, with sizes ranging 2.00" I.D.s - down to biocompatible capillary tubing with passages as small as .001".

Variations are boundless with basic options available that include radiopacity, pigmentation, visual identifiers, color coding, scoring, coextrusion and multiple passage Multi-Lumen extrusions.

 

ZEUS engineers, technical personnel and trouble shooters are a support team that stays up-to-date with the latest advances in medical device product development. As a part of your R&D, ZEUS can assist in ways to eliminate waste while enhancing productivity through increased line speeds and improved yields.

Etching - A Bond With Consistency

 

Recognized as being the world leader in medical and industrial etching technology.